Packaging Details Jeidar UPS Wooden Carton/ Standard Boxes, OEM Carton, Netural Brand Carton
Delivery Time 14 Business after payment confirmation


- DSP, CPLD, MCU Controls
- Output Power Factor 0.9
- Parallel upto 8 Unit with common BAT Bank
- 7 Inch Color Touch Screen


Product Description

1. High Performance Index

  • Advanced IGBT Rectifier and Inverter Technology. Input THDI4%, Input Power Factor0.99 to save more energy.
  • DT Series adapts the 5th generation IGBT Inverter control technology to enhance the output voltage/current performance. Online 3 Phase input and 3 Phase output double conversion structure to adapt 380/400/415V, 50/60Hz Mains Grid Supply Systems.
  • Output Power Factor 0.9 to carry 12.5% load capacities than traditional UPS.
  • Wide Input Voltage Range 380Vac (-45% to +25%) or 210-475 Vac with 50/60Hz ±5% Frequency Range. High adaptive capacity and Generator Capability.
  • Overall Efficiency upto 95%. Can reach to 98% on ECO Mode.
  • Powerful overload ability with output short circuit protection technology:  110%-120% overloads for 10 minutes.125%-150% for 1 minute.
  • Flexible Battery Configuration. It can be set on the front panel with 28/30/32 Units of Batteries.

2.2 Safe and Reliable

  • DT Series adapts DSP technology to control UPS all kinds of power function processes (including Parallel function) in order to increase system reliability.
  • Cooling System internal parallel design to enhance system safety.
  • Selection of Single or Dual Utility Input to enhance the utility power protection.
  • Self-Evaluation and Alarm of Phase Misconnection or Lost.
  • Front Modular Maintenance Design. MTBF can be upto 300K Hours.
  • 90% of system components are from international famous brands. All devices has been aged and fully tested for at least 24 hours before leaving the factory.

3. Various Optional Accessories.

  • Multiple communication interfaces integrated (RS232, RS485, Dry Contact, EPO, Battery Compensator, Etc.)
  • Optional SNMPcommunication adapter available.

4. Technologies

  • Multiple DSP, CPLD, MCU Full-Digitized Control to increase system consistency and reliability.
  • Output Power Factor 0.9 to enhance the load carry-abilities. (Can Carry 12.5% More Loads Capacity than Traditional UPS)
  • Full-digital current control and non-prioritized parallel technologies (up to 8 units)
  • High Loads Compatibility and Output Overload Ability to ensure safety
  • User Friendly and Intuitive 7 inch Color-touch Screen
  • Multiple Harmonic Wave Suppression Technology to ensure green power concepts
  • Various Optional Accessories (SNMP, Parallel Communication Port, Battery Communication Port, EPO, RS-232)
  • Power Control System Redundancy design increases the reliability of UPS control systems.
  • Independent Cooling system and comprehensive protection design stabilize system consistency and reliability
  • Intelligent Battery Management System to extend battery life. Battery Units can be set on the front screen with 28/30/32 Units.

Product Pictures


Overall View

Front View

Touch Screen

Top View

Function View









Host Machine Parameters

Overall Efficiency (Full Load)


Parallel Redundancy

Up to 8 Units With Common Battery Bank


Overload, Over Temp, Utility Power Voltage Fluctuation, Battery Voltage Over high or low.

DC Start


Generator Capability



7 Inch Color Touch Screen

Rectifier Parameters

Input Voltage


Input Voltage Range


Input Frequency Range


Input Power Factor


Inverter Parameters

Output Voltage

Line Voltage: 380×(1±1%)AC or Phase Voltage 220×(1±1%)AC

Output Power Factor


Output Voltage Stability

380±1%(Static Load) 380±2%(50-0% Load Change) 380±3%(100-0% Load Change)

Output Frequency

50Hz ±8%(Bypass Tacking input frequency;When bypass input frequency is over±8% or under BAT mode, output voltage is within±0.1%)

Output Waveform

Pure Sine Wave


<1%(Linear Load),<3%(100% Non-Linear Load)

3 Phase Unbalanced Load

3 Phases allow 100% Unbalanced Loads

Output Voltage Unbalanced Degree

≤1°(Balanced Load)

Input Output Phase Switch

≤1°(Balanced Load)


110<Load<125%: 10 Mins

125%<Load<150%: 1 Mins

Crest Ratio


Bypass Parameters

Static Bypass Input Range


Bypass-INV Transfer Time


Utility-BAT Transfer Time


Frequency Tracking Rate


Manual Maintenance Bypass


Nominal Voltage/ Rated Charging Voltage

28 Units


30 Units


32 Units


Communication Interface Parameters

Communication Interface


Physical Parameters


(W×D×H mm)


Weight kg



Company Information



l         Established in 1993, Jeidar has been specialized in the research, manufacture, sales and services of UPS productions for more than 20 years.

l         Jeidar has been honored as national and Shenzhen High-tech enterprise recognized by Chinese Government.

l         Customers from various industries including finance, tax, securities, insurance, postal services, telecommunications, transportation, public security, electricity, education, military and other large users with trust and praise.


l         Jeidar UPS believes in advanced technology, high reliability and high availability, quality, cost-effective and outstanding service.

l         Strong and Innovative R&D Department to handle different types of UPS Projects. We are not just selling UPS; We are power supply solution provider.

l         Fast response service team. We are always ready to serve you.

l         Experienced Overseas Sales Department. Our team members are coming from all around the world (United Kingdom, United States) with high educational background (Masters, Cornell University, University of Southern California, etc.)


"Your Satisfaction, Our Motivation" is Jeidar commitment to all our customers. Customers can follow our official website and other social media platforms for technical supports, power solutions, and other related consulting with our Jeidar Power Specialists:

l         Comprehensive Project requirements and specification consulting

l         Installation Instructions

l         Technical Supports

l         Roadmap for specific customizations 





TUV Certification

National High-Tech Enterprise Certification

TLC Certification


Packaging & Shipping

Packaging: Standard Safety Export Wooden Transportation Package.
Delivery Date: 3 Weeks After Payment (Deposit) has been received deposit. Delivery Date will be varied according to actual order quantity and customizations.


Internal Packaging


Package Top View

Exteranal Packaging View



Please Contact us if you have any question about our service or product. Our Service team will be ready to answer your question as soon as possible. Hope to have future businesses with you soon.  



Transaction History of the Supplier

Below is the information about the supplier's transactions conducted via Alibaba.com. If you require further details regarding the transaction data, please contact the supplier directly.

Transaction Overview


Transaction Details

This supplier has completedtransactions with buyers from .

Shipping Destination
Transaction Value
Transaction Date
Email to this supplier
Trade Assurance
China (Mainland)
Transaction Level:
Supplier Assessments:
2 Transactions 3,000+
The supplier’s transactions conducted via Alibaba.com in the past 6 months.
The supplier supports Trade Assurance – A free service that protects your orders from payment to delivery.
Supplier's Trade Assurance Limit: US $70,000
Learn More